3.5 Revision Arthroplasty
The common failure modalities of TKR
The common failure modalities of TKR
Set of flashcards Details
Flashcards | 42 |
---|---|
Language | Deutsch |
Category | Medical |
Level | Primary School |
Created / Updated | 06.03.2013 / 06.03.2013 |
Weblink |
https://card2brain.ch/box/3_5_revision_arthroplasty
|
Embed |
<iframe src="https://card2brain.ch/box/3_5_revision_arthroplasty/embed" width="780" height="150" scrolling="no" frameborder="0"></iframe>
|
01. The most usual cause of mechanical failure is
02. Large amounts of polyethylene debris can cuse
03. What can be the consequence of malalignment or too much constraint?
04. The early signs of prosthetic loosening are
05. Radiolucent lines are not uncommon around the tibia, even in well-fixed implants.
06. Lucent lines greater than 2mm or lines increasing in size over time indicate a potential failure
07. Compressive bone strength of the proximal tibia is greatest in the :
08. The strength of femoral metaphyseal bone is generally higher than that of the tibia
16. The TC3 tibial bearing insert has the same bearing geometry as the Sigma PS insert
18. Sigma femoral stems augments are manufactured from
19. Sigma femoral stem extensions are available in
??20. Sigma femoral augments can be used in combination
??21. Sigma Modular Plus augments are available in
3.5S94
22. Sigma Press-fit tibial stem extensions are available in
23. The LCS Compete unconstrained femoral component allow the use of condylar augments and steam extension
24. VVC is an acronym for:
25. The LCS Complete VVC femoral component allows the use of condylar augments and stem extensions
26. The LCS Complete VVC femoral component has the same external geometry as the LCS Complete femoral component
27. Femoral metaphyseal sleeves can be used with all femoral components
28. M.B.T. revision tibial components have the same plateau dimension as the standard M.B.T. component
29. M.B.T. revision platform accept tibial block augments
??30. M.B.T. block augments are the same shape as Sigma modular augments
3.5S103
31. Tibial sleeves can be used with block augments
??32. Tibial stem extensions can be used with M.B.T. revision components
3.5S103
33. Hinge knees are recommended for
34. The Noiles Rotating Hinge (NRH) flexes to
35. The NRH is manufactured from
36. The single curve of the femoral component sagittal profile is designed to
37. The hinge pin provides M/L and A/P stability
38. The polyethylene bumb stop limits hyper extension to
39. The NRH femoral coronal geometry is
??40. The NRH bearing does not suffer edge loading because
3.5S105