Velis Electro
Operational Parameters and Checklists
Operational Parameters and Checklists
20
0.0 (0)
Fichier Détails
| Cartes-fiches | 20 |
|---|---|
| Langue | English |
| Catégorie | Code de la route |
| Niveau | Autres |
| Crée / Actualisé | 27.09.2025 / 04.10.2025 |
| Lien de web |
https://card2brain.ch/cards/20250927_velis_electro
|
| Intégrer |
<iframe src="https://card2brain.ch/box/20250927_velis_electro/embed" width="780" height="150" scrolling="no" frameborder="0"></iframe>
|
Vne
108
Vfe flaps 1
81
Vfe flaps 2
65
Vs0
46
Vs
53
Best Glide Speed
70 KIAS
Power setting T/O
>=50 kW
Power Setting Cruise
20-36 kW
Power Setting Climb
Up to 48 kW (MCP)
Run Up
1. Parking brake - set
2. Zone behind A/C - clear
3. Power lever - full
4. Power EPSI - >50 kW
5. Power lever - idle
6. EPSI system page - 2 batteries active
7. EPSI engine / bat temp - checked
8. EPSI annunciator / warning panel - no warnings
Line Up Check
- Doors & windows - closed & locked both sides
- Time - noted
- Transponder - ACS
- Approach sector & runway - clear
Climb Check
- Flaps - Up
- Climb power - set (48kW)
Cruise Check
- Altimeter - set (STD - QNH)
- Flight instruments - checked
- Cruise power - 21-28 kW (36 kW max continuous
- EPSI SOC - checked, endurance
- EPSI temperatures - checked
Descent check
- ATIS or AD information - noted
- Approach briefing - completed
- Avionics - set & checked
- Circuit breakers - checked
- Cabin & Pax - secured
Approach check
- Altimeter - set QNH
- SOC - checked min 35% (50% bei Föhn)
Landing check
- Flaps - set for landing
- Approach sector & runway
- Windsock - checked
Va
100
V initial app
70 - 75
V intermefdiate app
65
V final app
60