Airframe & Systems Interne Prüfungen 2
LAT Bremen
LAT Bremen
-
- 1 / 54
-
Flashcards
What means "diluter-demand" concerning the flight deck oxygen mask?
When this mode is selected, the mask provides
oxygen mixed with ambient air,
and only when inhaling.
Name the operational modes of a flight deck oxygen system
normal (diltuter-demand) (1)
100% Oxygen (1)
emergency (100% Oxygen, constant flow) (2)
Passenger Oxygen system:
Describe the operation of an oxygen generator
The generator starts if the mask is pulled.
In the generator a burning process generates oxygen for passenger use.
Once initiated, the process cannot be interrupted.
How is the passenger oxygen system activated if oxygen generators are used?
- The passenger oxygen masks are provided by releasing (drop down)
- if the cabin pressure altitude exceeds the limit or when the system is activated by the respective switch in the flight deck.
- The system is "armed" by releasing the passenger oxygen masks.
- The oxygen supply is initiated by pulling one of the generator's oxygen masks.
List the correct actions that are required to get automatic deployment of ground spoilers after landing touch down (auto spoiler) and to retract the spoilers
- during approach, in-flight prior to landing: speed brake lever in ARMED position
- after touch down, extension : load on landing gear shock strut (compression) and wheel spin up
- for retraction: speed brake lever in DOWN position
A cabin door of a large transport aeroplane (e.g. A320) is used as an emergency exit.
Describe its features and operation
The door is marked at the outside and has a sign "exit" at the cabin side,
door handles are at the cabin side and at the outside,
as a large door at a hight of more than 6 ft, it is equipped with a slide,
the slide is automatically inflated when opened in "flight"-mode
slide inflation is arranged by the help of nitrogen expanding from a self contained slide inflation bottle.