02_DSC-21 Air Conditioning/Pressurization/Ventilation
DSC-21 Air Conditioning/Pressurization/Ventilation
DSC-21 Air Conditioning/Pressurization/Ventilation
-
- 1 / 26
-
Cartes-fiches
air is supllied by the pneumatic system via:
a) two pack flow control valves
b) Two packs
c) mixing unit, which mixed the air that comes from the cabin and the packs
- Air conditioning:
- Air conditioning:
1. air to the primary heat exchanger
2. cooled air enters the compressor è higher pressure + Temperature
3. cooled again in the MAIN heat exchanger (water) and enters the turbine, where its expand => generator power for compressor and cooling air fan
- removal of energy during process reduces air temperature
- water separator system dries air before turbine section
- Ram Air:
- Ram Air: to remove smoke => ON: outflow valve opens about 50% when under automatic control and differential pressure less than 1 PSI
- Hot Air pressure regulating valve:
- Hot Air pressure regulating valve: closed when: a) ducts overheat b) cockpit trim air valve fails c) both cabin trim air valves fail (remain open, even when forward or aft cabin air valve fails)
- Pack controller:
- Pack controller: closed when TO PWR is set + ldg gear compressed and ldg gear compressed and speed at or above 70 kts => open 20 s after below 70 kts
- Temperature sensors:
- Temperature sensors: a) in the cockpit b) lavatory extractions and galley ventilation
ECAM (
ECAM (Electronic Centralized Aircraft Monitoring)
- Zone controller failure:
a) primary:
b) both:
Zone controller failure:
a) primary: secondary as backup => flow setting and optimized temperature regulation are not available è HOT AIR and TRIM AIR valves close
Zones are controlled to 24 Grad => Pack 1 cockpit Pack 2 cabin
ALTN MODE appears in the ECAM (Electronic Centralized Aircraft Monitoring)
b) both: Optimazied and bacup are lost => packs delivery fixed temperature: 20 for PAX 1 and 10 for PAX 2
- Failure removes all info from ECAM COND, which then displays PACK REG
Pack controllers:
Pimary:
Both:
- Pack controllers:
Pimary: Regulation is not optimized and Pack flow is fixed at the previous setting
Both: As backup outlet temperature is controlled by the anti-ice valve (5 and 30 degrees in max. of 6 min)
- Ecam signals are lost
Air conditioning system controllers:
One:
Both:
Air conditioning system controllers:
One: no affect, second takes over
Both: related pack is lost and hot air pressure regulating valve + trim air valves remain closed
ACM
ACM (air cycle machine)
- ACM (air cycle machine) failure:
- ACM (air cycle machine) failure: the affected pack may be operated in heat exchanger cooling mode
Failure of the hot air pressure regulating valve:
- open
- closed
Failure of the hot air pressure regulating valve:
Failed Open: no affect
Closed: optimized regulation is lost => trim valves to closed position => Pack1: cockpit pack2: Cabin
- HOT AIR pushbutton: FAULT when overheat
- HOT AIR pushbutton: FAULT when overheat (over 88 degrees) => off when below 70 degrees or crew select off
- PACK pb: closed when: a,b,c
- PACK pb: closed when: a) upstream pressure below min. b) compressor overheat c) engine start (when on IGN) N2 < 50% ==> on ground reopening of the valves is delayed for 30s to avoid a suppl. Pack closure cycle during second engine start
- Pack flow: low= xy%?
- Pack flow: low=80%, norm=100%, High=120%
- in single pack ops or APU => HI automatically
- if LOW and cooling demand not satisfied => automatically to 100%