how many screens can one SG power?

4

what indication in the PFD is lost, if ADC fails?

ALT and SPD tape

what indication in the PFD is lost, if IRS fails?

ATT and HDG

SPD trend how many seconds?

10s

ALT trend how many seconds?

6s

max ALT for APU ops?

45'000ft (but only if started at 37'000ft)

max APU starting ALT?

37'000ft

max ALT to use APU bleed air?

30'000ft

which BUS is the RAT powering?

AC ESS BUS

which tree condition inhibit an automatic wing fuel transfer?

  • flap posi >0 in flight with gear down
  • either wing tank below 600lb
  • DC aux pump suppl fuel feed (AC pump failure)

 

which fuel pumps have no pilot control?

center tank transfer pumps

which combination makes the center tank fuel unusable?

  • each wing is not full at departure
  • planned cruise alt <30'000ft

fuel load per wingtank, pressure refueling?

15'050lbs

center tank capacity

9150 lbs

above which fuel load no towing without electrical power?

>12'500lbs

in what timerange after ENG shutdown may the ENG oil be replenished?

5-30min

in what timerange after APU shutdown may the APU oil be replenished?

15-45min

lowest fuel temperature for T/O?

5°C

max ENG ITT start on GND?

700°C

max ENG ITT start in the air?

850°C

max tailwind limittation for ENG start?

20kt

(crank ENG for 30s, followed by immediate AUTO start)

In an emergency, what buses 
are powered by the batteries

BATT BUS and DC EMER BUS

What are the four main DC buses?

1. DC Bus 1, 
2. DC Bus 2, 
3. DC ESS Bus, 
4. BATT Bus

when do the GLD (ground lift dumping) device arm?

45kt

HYD: in AUTO, when come the ACMP on line automatically?

  1. Slats/Flaps out of IN/0°, motion stopped
  2. primary pump (EDP 3A) below 1800psi

what are HYD sys 1+2 powered by?

  1. one EDP
  2. one ACMP

HYD: methods to interrupt hydraulic fluid from reservoir to EDP?

  1. pressing HYD shut off valve
  2. pulling fire handle

ELEC: how many AC buses on the Global?

8

4 primary buses in the ACPC

4 feeder buses in the CCBP

 

ELEC: what does selecting of DC emergency override does

both ESS TRU's bypass the DCPC and directly go to the SPDA's

FLT CONTR: what indications when stall computer detects a stall?

  • low speed cue in amber
  • ignition on
  • shaker
  • AP disengages
  • stall aural sound
  • pitch disconnect system locks
  • "STALL" in PFD
  • stick pusher

IAM: max alt for AUX pressurisation?

41'000ft